Radioisotope fume hoods are generally designed to guard users from radioactive
materials. Radioactive isotope is any of the several species of the identical
element with different masses whose nuclei are unstable and it'll dissipate the
surplus energy by emitting radiation such as alpha, gamma and beta rays. So, when
the working persons inhale the radio isotopes, it'll get into different organs and
can cause several effects which can may result in death.
Radioisotope fume hoods are specifically designed for people handling radioactive
materials. This fume hood is created with stainless-steel internal surfaces with
coved seamless welded corners to forestall material build-up and also to stop
contamination. To withstand the burden of lead shielding plates and lead laced
sashes, specially constructed worktops are provided. These fume hoods will also
provide containment performance kind of like that of high-performance low velocity
fume hoods. It should be ensuring to produce maximum safety during working with
radiopharmaceuticals and other radioactive materials
This hood is created from double wall construction for greater strength and
robustness. The superstructure of radioisotope hoods is usually made stronger than
that of conventional hoods so as to support lead bricks and other shieling required
within the hood. Interior stainless steel work surface should be water tight and
reinforced to ensure the support up to 200 lbs per square foot.
Benefits
Smooth coved corners
Reinforced work surface
Excellent aesthetics
Superior containment at 0.3m/s
High energy savings
Technical specifications
MOC
CRCA 18G Epoxy powder coated
Stand
SS 304 pipe
Working table top
SS 304 powder coated sheet covered SS 304 sheet
Exhaust system
Motor Blower assembly covered with GI sheet
Sash/Door
Vertical folding type
Air velocity
0.5 m/s
Noise Level
65 dBA
Glass window
Two layer toughened glass, 5 mm thickness
Adjustable height
Motor control
Make up air
Air needed to replace the air exhausted from a room by the fume hood and
other ventilation devices
Face velocity
The velocity of the air passing through the work opening of the fume hood
measured in the plane of the sash. Measured in feet per minute (fpm), or
liters per minute
Electrical fittings
Electrical sockets and MCB switch
Illumination
Fluorescent lamp or UV lamp
Optional accessories
HEPA Filter, Caster wheels, Horizontal sash, SS 314 / SS 316 MOC,
Temperature indicator, Face Velocity Meter, Airflow Indicator, Audio /
Visual alarm
Power supply
220 / 230 V
Dimensions
Model No.
CFM @29″
CFM @18″
Super structure (WxHxD mm)
Worktop (WxHxD mm)
Hood opening (WxH mm)
W
H
D
W
H
D
W
H
DRFH-90
567
354
915
1425
845
915
40
762
660
740
DRFH-120
833
521
1220
1425
845
1220
40
762
965
740
DRFH-150
1100
688
1525
1425
845
1525
40
762
1270
740
DRFH-180
1367
854
1830
1425
845
1830
40
762
1575
740
DRFH-240
1900
1188
2440
1425
845
2440
40
762
2185
740
Accessories
Airflow monitor
Flexible duct
Sash made of PC
Variable air flow control
Self contained suction.
Contact Information
Phone Number
+91 842 823 1593 | +91 995 287 7991
Email Address
sales@drizgas.com | info@drizgas.com
Office Address
No. 50, Villianur Main Road, Odiyampet, Puducherry - 605 110, INDIA