General Purpose Fume hood are used for extracting mild acidic/alkaline or
solvents fumes during chemical reactions.General purpose fume hood also called
as “fume cupboard” or “fume closet”. Fume hood are only source of lab
ventilation Exposure controls of laboratory include equipment and
procedures designed to reduce inhalation, skin absorption, or ingestion of hazardous
materials.
A properly functioning and properly used fume hood can reduce or eliminate exposure
to volatile liquids, explosion protection, dusts, and mists. It is desirable to use
a laboratory hood when working with all hazardous substances.Fume hoods when sized
with an appropriate chemical resistant centrifugal exhaust fan will protect
laboratory staff from exposure to harmful fumes
Working principle of fume hood
The air is sucked from the front which is the open side of the cupboard, slots and
baffles direct the air flow to the atmosphere. Air foils at bottom and side edges
allows uniform air flow to the work surface with minimum turbulence.The air being
exhausted is either expelled outside the building or made safe through filtration
and fed back into the lab area. The recirculated air is not permitted to
non-laboratory areas as they are kept isolated.So that users may be protected from
hazardous fume & gases expelled during any experiment.Horizontal /vertical sash can
be used for protective shielding.There is to be an adequate volume of air available
or the fume-hood won’t be able to draw a sufficient volume of air to function
properly.
There are two type of fume hoods
Ducted Fume Hoods: These Fume Hoods are used for industrial purpose.
The air is drawn from the lab space into the fume hood and then dispersed through
ducts into the outside atmosphere.
Ductless Fume Hoods: In this Fume hood the air is treated and
recirculated instead of venting it directly to atmosphere. Fan is mounted on the top
of the hood, or below the worktop. Air is drawn through the front opening of the
hood and goes through the filter, before passing through the fan and it is
recirculated back to the workplace. For a ductless fume hood, filter medium is
essential to remove hazardous and noxious substances.Advantage of ductless
fume hood, they are mobile, energy saving and easy to install.
Technical specifications
MOC
CRCA 18G Epoxy powder coated
Stand
MS pipe, 18 G powder coated
Working table top
MS powder coated sheet covered with PP sheet
Exhaust system
Motor Blower assembly covered with GI sheet
Sash/Door
Vertical folding type
Air velocity
0.5 m/s
Noise Level
65 dBA
Glass window
Two layer toughened glass, 5 mm thickness
Adjustable height
Motor control
Make up air
Air needed to replace the air exhausted from a room by the fume hood and
other ventilation devices
Face velocity
The velocity of the air passing through the work opening of the fume hood
measured in the plane of the sash. Measured in feet per minute (fpm), or
liters per minute
Electrical fittings
Electrical sockets and MCB switch
Illumination
Fluorescent lamp or UV lamp
Optional accessories
HEPA Filter, Caster wheels, Horizontal sash, SS 314 / SS 316 MOC,
Temperature indicator, Face Velocity Meter, Airflow Indicator, Audio /
Visual alarm
Power supply
220 / 230 V
Dimensions
Model No.
CFM @29″
CFM @18″
Super structure (WxHxD mm)
Worktop (WxHxD mm)
Hood opening (WxH mm)
W
H
D
W
H
D
W
H
DGFH-90
567
354
915
1425
845
915
40
762
660
740
DGFH-120
833
521
1220
1425
845
1220
762
965
740
DGFH-150
1100
688
1525
1425
845
1525
762
1270
740
DGFH-180
1367
854
1830
1425
845
1830
762
1575
740
DGFH-240
1900
1188
2440
1425
845
2440
762
2185
740
Accessories
Fume hood base cabinet
Blower
Fan ON/OFF switch
Ceiling enclosures
Electrical accessories
Light On/OFF switch
Features
Cleanand chemical resistant interior
Sash stop limit and air flow monitoring system
Optional –Sensors for activating alarm when gas leaks out of the
hood.